Ducted Air Flow Measurement
Measuring ducted air flow with accurate and reliable measurement equipment from Air Monitor allows your building’s HVAC systems to effectively and efficiently meet energy conservation and health & safety requirements.Mechanical ductwork continues to serve as the most common method for distributing conditioned air in commercial buildings. The controlled dimensions and well-defined construction of a building’s duct network often serve as the best place to gather accurate airflow measurements.
Accurate HVAC airflow measurements in complex ductwork
Air Monitor’s duct air flow measuring devices, transmitters and stations are unrivaled in their ability to accurately measure flow in the most challenging duct configurations. They can be easily installed in both new and existing systems. The products below are commonly used for this application.Easily calibrate airflow signal transmissions with utmost accuracy
The most critical and demanding HVAC and industrial applications require highly accurate and stable signal transmission. Air Monitor transmitters can be easily configured and calibrated and can transmit air flow measurements in ultra-low differential pressure and flow applications with ±0.1% of natural span accuracy.AMCA Certified Airflow Measurement Stations
Air Monitor’s Airflow Measuring Stations, such as the FAN-E Station and the VOLU-probe/VS Station, are licensed to bear the AMCA Certified Ratings Seal for Airflow Measurement Station Performance. This certification ensures extremely accurate airflow measurements (2% of actual flow or better) under turbulent, rotating, and multi-directional air flows normally present in discharge ducts.ELECTRA-flo 5 Series Thermal Airflow Measurement System
The ELECTRA-flo Thermal Probe Array utilizes thermal dispersion technology in multi-point probes to measure average airflow and temperature. The rugged anodized aluminum probes have aerodynamic sensor apertures that condition turbulent airflow, resulting in a NIST traceable accuracy of ±2% of actual flow. Each probe array comes complete with an ELECTRA-flo G5 Transmitter that provides connectivity to BACnet MS/TP or Modbus RTU networks. Two analog outputs are also available for airflow and temperature.
ELECTRA-flo/S5-CM Thermal Airflow Measurement Station
ELECTRA-flo/S5-CM thermal duct air flow measuring stations combine thermal dispersion measurement technology with an integral honeycomb cell air straightener to assure measurement accuracy within ±2-3%. The addition of the honeycomb cell air straightener is vital to obtain these degrees of accuracy under turbulent, rotating and multi-directional airflows normally present near fan inlets or discharge ducts. Each station is accompanied by an ELECTRA-flo G5 Transmitter with several connectivity options.
FAN-E Pitot Airflow Measurement Traverse Station
The FAN-E Station is a multi-point, self-averaging Pitot traverse station with an integral air straightening honeycomb cell. It’s capable of continuously measuring ducted airflow with a certified accuracy of ±2% when tested according to AMCA Standard 610. The high degree of accuracy is a result of the sensor locations and sensing ports, the honeycomb airflow processing, and the instantaneous pneumatic averaging of multiple pressure values. The FAN-E Station is designed for applications with very limited straight duct runs and/or highly disturbed airflow.
VOLU-probe Pitot Airflow Measurement Traverse Probe
The VOLU-probe Airflow Traverse Probes consist of multiple Pitot total and static pressure sensing ports positioned along the length of each probe to traverse the duct cross-section. They average the sensed pressures in their separate internal manifolds and provide velocity pressure measurement accurate to within 2-3% of actual flow.
Several models are available for differently sized duct sides and configurations.
ELECTRA-flo/SD Thermal Airflow & Temperature Measurement System
The ELECTRA-flo/SD is an accurate, cost-effective thermal duct airflow measuring system specifically designed for VAV box installations and small duct applications using 4″-16″ ducts. The low flow measurement capability of the ELECTRA-flo/SD allows for reduced minimum airflow settings and increased system efficiencies while still meeting IAQ requirements. Installation and set-up are easy in both new and existing systems.
VELTRON II Transmitter
The VELTRON II is an ultra-low differential pressure “smart” transmitter designed to convert the low magnitude pressure signals generated by airflow stations and probes, or static pressure sensors into dual transmitter output signals (4- 20mA, 0-5VDC or 0-10VDC) linear to pressure or flow. Each VELTRON II is equipped with standard features which make it easy to calibrate and operate in a variety of configurations. To permit manual calibration of the VELTRON II, an electronic switch is provided to permit manual positioning of the zeroing valve.
VELTRON DPT 2500-plus Transmitter
The VELTRON DPT 2500-plus transmitter is furnished with an automatic zeroing circuit capable of electronically adjusting the transmitter zero at predetermined time intervals while simultaneously holding the transmitter output signal. The automatic zeroing circuit eliminates all output signal drift due to thermal, electronic or mechanical effects, as well as the need for initial or periodic transmitter zeroing. For transmitters operating in a moderately steady temperature location, this automatic zeroing function produces a “self-calibrating” transmitter.
VOLU-probe/VS Pitot Airflow Measurement Traverse Station
The VOLU-probe/VS Station utilizes one or more VOLU-probes, factory mounted in a rigid, welded, galvanized casing to sense and average separate total and static pressure traverses of an air stream. The station has a certified accuracy of ± 2% when tested in accordance with AMCA Standard 610. Each probe contains multiple sets of Pitot sensing ports positioned equidistantly along the length of the probe. They traverse the duct cross-section and average the sensed pressures in separate internal manifolds.
Aluminum LO-flo Pitot Airflow Measurement Traverse Station
Air Monitor’s Aluminum LO-flo Pitot Traverse Station combines a honeycomb air straightener-equalizer with proven multi-point, self-averaging Pitot technology. It can measure low air volumes of 35 to 1700 cubic feet per minute in small diameter round ducts between 4″ – 8″, with an accuracy of ±2% of actual airflow.
News & Innovation
Product Brochures & Catalog Sheets
Air Monitor measurement devices and systems are used for highly accurate measurement of airflow in HVAC ductwork. Download our industrial systems and individual product brochures for more information.Understanding How Thermal Dispersion Airflow Measurements Work
Air flow measurement devices are a fundamental component of building automation systems (BAS), which are used by HVAC contractors to monitor and control the performance of a facility.Installation Documents
Download product guides for assistance and help in locating and installing air flow transmitters and measurement equipment in round, rectangular or square ducts for optimal performance and maximum efficiency.-
Aluminum LO-flo Pitot Airflow Measurement Traverse Station
-
ELECTRA-flo 5 Series Thermal Airflow Measurement System
-
ELECTRA-flo/CM Thermal Airflow Measurement Station
-
ELECTRA-flo/SD Thermal Airflow & Temperature Measurement System
-
FAN-E Pitot Airflow Measurement Traverse Station
-
VELTRON DPT 2500-plus Transmitter
-
VELTRON II Transmitter
-
VELTRON III Transmitter
-